Tetra® LED Systems Power Supply

GEPS12-60U-GL (120-277 VAC input / 12 VDC output / 60 W)

 

Power Supply Features

• Supports all 12 VDC Tetra Channel Letters, Box signs and Tape Product

• Dry and damp location rated
• Class 2 wiring per NEC Article 725 (SELV) • IP66 rated: separate enclosure required

Power Supply LEDs

£27.50Price
Power Supply
Quantity
  • Tetra® LED Systems Power Supply 

    GEPS12-60U-GL (120-277 VAC input / 12 VDC output / 60 W)

    Power Supply Features

    • Supports all 12 VDC Tetra Channel Letters, Box signs and Tape Product

    • Dry and damp location rated
    • Class 2 wiring per NEC Article 725 (SELV) • IP66 rated: separate enclosure required

    BEFORE YOU BEGIN

    Read these instructions completely and carefully.

    RISK OF ELECTRIC SHOCK

    • Disconnect power at fuse box or circuit breaker before servicing or installing product.
    • Properly ground Tetra® power supply.

    • Must be enclosed in a end product. RISK OF FIRE

    • Minimum 5 cm (2”) spacing from heat producing components required.
    • Minimum 10 cm (4”) to side and 2.5 cm (1”) spacing in compartment surrounding component required.
    • Application considerations potentially requiring additional spacing include high ambient temperature seen by the power supply, poor contact with a heat dissipating material, inadequate ventilation, or direct exposure to sun.
    • Use only Tetra® supply wire to make connection from Tetra® power supply to Tetra® LED strip.
    • Use only approved wire for input/output connection. Minimum size 18 AWG (0.82 mm2).
    • Follow all local codes.

    RISK OF INJURY

    • While performing installations described, gloves, safety glasses or goggles should be worn.

    Save These Instructions

    Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

    Prepare Electrical Wiring

    Electrical Requirements

    • Limited to use in dry and damp locations.

    • The suitability of rain enclosure shall be determined if

      intended for wet location.

    • The grounding and bonding of the LED Driver shall be done

      in accordance with National Electric Code (NEC) Article 600.

    • Follow all National Electric Codes (NEC) and local codes.

    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

    Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area

    is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

    This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.

     